trim, chimney floor hole

The first screw-up for today was the 1x2s from Home Depot. 

They are most certainly not 1x2s.  A one-by-two, of course, is not 1″ by 2″, but 1-1/2″ x 3/4″.  However, these are not 3/4″.  They’re 5/8″.  I’ll be taking them back tomorrow morning.  More shrinkflation. 

I needed to rip 1x2s down to 3/4″ square to act as filler between the window frame and trim.  Instead, I ripped some old 1x6s down. 

Read more

showing, more electrical

I’m using the laundry room as an admin office.  Someone is coming by to see the place.  However, the dang printer doesn’t work; too much dust is messing up the sensors, I think. 

More electrical work was done today along with putting in faceplates.  The one without is the 120VAC line-voltage thermostat for the mudroom.  It is the only baseboard heating in the suite, so I went with a simple 14-2 wire 15A 1P line. 

For some unknown reason, the front exterior lights stopped working.  As it turns out, the neutral (white) wire was not fastened properly.  But it works now. 

switches, trim boards

The buying of electrical supplies never seems to end!

Neighbour Dave suggested green would be a good colour for the front door since the house evidently was trimmed in green long ago.  I got this green from Home Depot.  I can’t wait to paint the door!  But I have to wait to paint the door as there are lots of other priorities to complete the suite.

Read more

toilet shelf, scorched outlet, trim boards

Well it isn’t perfect, but it will have to do.  The resin cured fairly well, and it looks okay.  There are four shelves that will look like this. 

This certainly isn’t perfect, and it cannot exist.  I suspect that the breaker did not deactivate when too much resistance melted this localized area.  There was nothing left of the old wiring to know if it was caused by a knife nick, faulty screw connection, or what-have-you.  The old Stab-lok breakers have been replaced with new ones that comply to UL standards.  I replaced an outlet scorched like this a month after the previous tenants moved in. 

More trim boards were treated with polyurethane and left to cure.  

Read more

heat duct, door adjust and paint

One of the heat ducts became loose. 

Outlets were attached. 

Paint began on the doors. 

The door for bedroom 2 was maladjusted.  How?  It was put in before the house was straightened and levelled, so, thus, it was realigned with the world. 

The bathroom door was painted along with the bedroom 2 door. 

Window frames were also painted. 

exterior outlets, drywall, window framing, bare wood

The veranda outlet wire was put in a while back.  I’m just now getting around to connecting it.  It’s a 15-amp GFI (ground fault interrupter) outlet. 

To get this wall finished, in terms of drywall, the bottom strip had to be attached.  It varied around 3 1/2″.  With levelling the house done a few days ago, we could finally complete this wall.  It could not be done previously as the slightest movement would crack the newly taped and mudded drywall. 

There is a problem with the outlet at the west side of the building (near the front parking area).  It seems that every 20A outlet is tamper resistant, making it very difficult to plug in anything.  This was fixed. 

The veranda outlet was covered and sealed to the outlet box and wall.  Those outlet covers with the little metal flaps or one large metal flap are not used anymore. 

On to the window framing.  These living room windows (new small and old large) do not include frame extensions to fit 2×4, 2×6, or 2×8 walls, so interior framing had to be added.  This is a dry fit.  Paint will come later. 

However, I’m a softy for nice lumber markings.  Because of the colouration of this wood, I couldn’t bear to paint this bare wood.  I’ll save the piece for another project that doesn’t cover it up. 

outlets, switches, gaps, fillers

We begin again.  This is where we left off last time – with a temporary floor. 

I noticed, when putting a cover on the outside GFI for block heaters, that nothing would plug in.  The outlet was stuck.  I see now that it is a tamper resistant outlet.  In other words, it has some piece of plastic in there to prevent things from being plugged in.  Dave noticed and told me about it earlier in the year when he was plugging in the cement mixer.  As it turns out, all GFI (or, at any rate, all 20A GFI) duplex receptacles are tamper resistant.  I went to Home Depot to get one that isn’t, but they didn’t have any.  Dunno what I’m going to do here.  More on that later. 

Read more

living room window in, skim coat on

Time to put in a temporary floor so we can get the window in.  I picked up some treated 1/2″ plywood from Lealta Building Supplies.  The counter guy game me some good advice about later painting the surface of this.  It will be two layers of 1/2″ instead of one 3/4″ ply and one 1/4″ paintable ply. 

The window is in.  Dave and I hoisted the window up on its frame and  s l o w l y  carried it to the veranda where we rested it on three upturned buckets.  We put a 1×4 across the opening on the inside so the window wouldn’t just fall in. 

Read more

window caulk, cable

The large living room window was turned up-side-down, and I put a bead of Flex Paste in the interior gap.  This stuff is hard to squeeze out of the tube.  But, for $22 a tube, it is likely better than simple caulking.  Now I must wait for it to cure. 

In the mean time, I fitted the small living room window framing with exterior sheathing of 1/2″ OSB.  It is a smaller window than previously, so the gaps need to be filled and sealed. 

Next, tape flashing to seal up the gaps. 

Read more